EU tender Subsea inspection and repair campaigns
II.1.2) Pagrindinis BVPŽ kodas:
98363000
Narų paslaugos
;
II.1.3) Sutarties tipas:
Paslaugos
II.1.4) Trumpas aprašymas:
Ørsted Wind Power A/S is undertaking Structural Inspection Below Water (SIBW) on annual basis and repairs on demand on our offshore wind farms.
The SIBW and repairs are planned cross-portfolio meaning all Ørsted sites in operation in:
- Germany: Borkum Riffgrund 01, 02 & 03, Gode Wind 01, 02 & 03
- Denmark: Horns Rev 02, Nysted Havmølle park and Anholt
- and the Netherlands: Borselle 01 & 02
The Services comprises the following:
General visual inspection
▪ Transition piece (TP)
▪ Monopile
▪ Jacket structures
▪ Support structures, including appurtenances
Close visual inspections of cable protection and route system
Performed on each cable route, with the following criterion:
• Cable positioning in cable protection system
• Cable exposure including inspection of cable protection system
• Horizontal and/or vertical cable free span from cable exit in cable protection system to seabed.
Anode cage design (only)
▪ Cleaning, check and maintenance of critical connections
Marine growth inspection
▪ Thickness readings covering soft and hard marine growth measurements taken from pre-determined cardinal points vertically and circumferentially.
Cathodic protection system (CPS) readings
▪ Cleaning of selected anodes to estimate anode depletion.
▪ Potential contact readings taken externally on the jacket/transmission piece (TP) and monopile
(MP) at pre-determined points both vertically and circumferentially
Note: It is only expected that the Supplier cleans as much as is required to get a reliable anode
depletion estimate or a minimum of 1m linear meter of each face.
Grouted connection designs (only)
▪ Close visual inspection of grout seal
▪ Cleaning (if needed) of grout seal followed by a close visual inspection
Cleaning of surface is requested for e.g. for close visual inspections as well as removal of ropes,
etc. entangled at ladder of foundation.
Removal of debris
Repairs
Repair of CPS and second steel structures e.g. bolted connections to be done on demand.
Diving (scratch samples) Investigation of growth and demersal megafauna on
underwater structures:
Recovery of lost objects
Investigations
R&D projects