Airija – Spektrometrai – UCC-VEAT-2025-03
Airija – Spektrometrai – UCC-VEAT-2025-03
I dalis: Perkančioji organizacija
I.1) Pavadinimas ir adresai:
Oficialus
pavadinimas: University College Cork
Adresas: University College Cork, 6 Elderwood, College Road
Miestas: Cork
Pašto
kodas: T12 VH39
Šalis: Airija
Asmuo
ryšiams:
El-paštas: procurement@ucc.ie
Interneto adresas (-ai):
Pagrindinis adresas: https://www.ucc.ie
II dalis: Objektas
II.1.1) Pavadinimas:
UCC-VEAT-2025-03
II.1.2) Pagrindinis BVPŽ kodas:
38433000
Spektrometrai
II.1.3) Sutarties tipas:
Kita
II.1.4) Trumpas aprašymas:
Voluntary ex-ante transparency notice
VEAT NOTICE
UCC reference number UCC-VEAT-2025-03
Short Description
The School of Chemistry at University College Cork (UCC) is seeking to procure a benchtop portable Nuclear Magnetic Resonance (NMR) system with a 90MHz field strength, very high sensitivity, narrow resolution and capable of multiple nuclei measurement without loss of sensitivity to support ongoing and future research activities. The system will be used in both teaching and research applications.
Technical Reasons for Award without Prior Publication:
As per Article 32 of EU Directive 2014-24, University College Cork wishes to avail of the negotiated procedure without prior publication because competition is absent for technical reasons.
While it is acknowledged that NMR Systems can be acquired from various vendors, Magritek GmbH system, SPINSOLVE 90 Multi-X ULTRA is the only benchtop system that with the combination of the following specifications.
Benchtop/Portable System
1H frequency: 90 MHz field strength
Sensitivity: >240:1 (for a dual channel model, sensitivity is measured following the ASTM method in a single scan on a 1% ethylbenzene sample dissolved in deuterated chloroform. The signal used for the calculation is the one of the methylene group and the noise is calculated for a signal free region between the aromatic and the methylene signals.) The higher the sensitivity, the faster the measurements (2x more S/N – 4 times faster) and the lower the concentrations possible that can be worked with. The system needs to be very sensitive with a very fast analysis time. This is a specific requirement for the research work planned and for training and teaching on the taught MSc in Analytical Chemistry programme.
Resolution: Linewidth at 50% <0.2 Hz, Linewidth at 0.55% <8 Hz, Linewidth at 0.11% <16 Hz. We require the best linewidth and narrowest resolution for the analytes of interest.
Multiple nuclei measurement capability - for example 1H, 19F, 13C, 31P, 23Na all on one system. We require multiple nuclei measurement on the same system without compromising the sensitivity.
II.2) Aprašymas:
II.2.1) Kitas (-i) šio pirkimo BVPŽ kodas (-ai):
38433000 Spektrometrai